20
3PCLIOBIM430
Displaying Special Statuses
The corresponding heater display alternates between two characters depending on the status.
Event Heater
status
Start
conditions
End
conditions Action
Heater
Display fore
(1 sec.)
Heater
Display back
(1 sec.)
Priority
Heater with residual
heat Off Heater
Temperature > 50ºC Heater
Temperature < 40ºC ---------- ‘H’ ‘H’ 3
Heater without pan On No pan or not suitable
pan over the heater Heater Off In 1 minute
Heater off ‘Power’ ‘υ’ 1
Induction generator
over temperature Off Heat sink
Temperature > 90ºC Heat sink
Temperature < 80ºC ---------- ‘ ’ or ‘H’ ‘c’ 2
Induction generator
over temperature On No power is
delivered to
the heater
‘Power’
Errors/Alarms
The corresponding heater display alternates between two characters depending on the Error.
APPLIANCE ERRORS
Event
(Visualization Priority Order) Description Action End
All Heater Displays
(fore 0.5 sec./ back 0.5 sec)
FalloKeyOnOffEmitter Security Key Error App Off (*) ---------- FA
FalloKeyOnOffReceiver Security Key Error App Off (*) ---------- FC
FalloNtcShort Touch NTc Error App Off (*) ---------- FE
FalloNtcOpen Touch NTc Error App Off (*) ---------- FP
FalloOverTemp Touch NTc Error App Off (*) T < 90ºC Fc
FalloEepromChecksum Eeprom Checksum Error App Off (*) ---------- FH
FalloAdc Security Key Error App Off (*) ---------- FJ
FalloSw Software Error App Off (*) ---------- F0
FalloAmbientLight Keyboard Error App Off (*) Light Condition FL
FalloDivisor Security Key Error App Off (*) ---------- FU
FalloTestLedOnOff OnOff Led Error App Off (*) ---------- Fd
FalloTetGroupSelection Keyboard Error App Off (*) ---------- Fb
(*) All heaters switched Off and locked
HEATER ERRORS
Event
(Visualization Priority Order)
Description Action End
Heater Display
(fore 0.5 sec./ back 0.5 sec)
FalloComunicaciones Communication Error
Induction Heaters Off(**)
Comm. OK F5
FalloNtcFocoShort Induction Heater Ntc Error
Heater Off(**)
Serial Comm. F1
FalloNtcFocoOpen Induction Heater Ntc Error
Heater Off(**)
Serial Comm. F2
FalloNtcFoco Induction Heater Ntc Error
Heater Off(**)
Serial Comm. F7
FalloNtcGeneradorShort Induction Ntc Error
Generator Off (***)
Serial Comm. F3
FalloNtcGeneradorOpen Induction Ntc Error
Generator Off (***)
Serial Comm. F4
FalloNtcGenerador Induction Ntc Error
Generator Off (***)
Serial Comm. F8
FalloNoRedGenerador Induction Error
Generator Off (***)
Serial Comm. F6
FalloOverLoadGenerador Induction Error
Generator Off (***)
Serial Comm. F9
(**) Heater switched off and locked